Insight · Dimensional stability
Moisture absorption and dimensional change in nylon
8 November 2026 · Himing New Material (Zhongshan CSII) Co., Ltd.
The short answer: most dimensional problems on nylon parts are not moulding faults but a mismatch between the state the part is inspected in and the state it was designed for. PA6 and PA66 take up moisture from the air, swell and lose stiffness; glass fibre dilutes the uptake without removing it. Decide first how humid the part will live and in which state it is measured, then cut the tool using that grade's measured moisture-expansion coefficient.
1. What moisture changes
| Property | Dry | Conditioned | Note |
|---|---|---|---|
| Tensile strength | Baseline (100%) | Down 15–40% | PA6 usually loses more than PA66; worse at temperature |
| Flexural modulus | Baseline (100%) | Down 20–50% | Stiffness loss exceeds strength loss; thin parts feel soft |
| Notched impact | Baseline | Rises | Water plasticises — tougher but less stiff |
| Dimensions | Baseline | 0.3–1.0% linear | Depends on grade and glass content; calculate from measured coefficients |
| Electrical | Baseline | Insulation falls | Assess CTI and volume resistivity in the hot-wet state |
Ranges are industry-typical and vary with grade, glass content, temperature and humidity; design values must come from the grade's measured data.
2. Estimating the dimensional increment
Three steps, rather than a single universal percentage:
- Establish the equilibrium moisture content at the service environment (temperature, humidity, wall thickness).
- Convert with the grade's moisture-expansion coefficient — the linear growth per 1% moisture.
- Apply the increment separately along and across the flow; glass-filled systems differ substantially between the two.
If a supplier gives water uptake but not an expansion coefficient, estimate from a similar system — but measure the critical conditioned dimensions on the first tool and correct before production. Skipping this step guarantees a dimensional fight later.
3. What each control actually does
Drying: controls moisture before moulding to prevent degradation and voids; it does not change what happens to the finished part.
Conditioning: brings parts close to service equilibrium before shipping, stabilising dimensions and properties early. Suits precision parts, but costs time and space and needs a defined conditioning spec.
Annealing: relieves stress and stabilises crystallinity, reducing later distortion and cracking; it does not stop absorption, only makes the drift more predictable.
4. Three common misjudgements
- Using dry dimensions as assembly dimensions. A part straight off the machine is the driest and smallest it will ever be; design to that and assembly runs tight.
- Ignoring ambient humidity. Equilibrium moisture differs between a wet coastal summer and a dry northern winter; the same tool behaves differently in two plants.
- Assuming glass stops absorption. The matrix still absorbs, and anisotropy grows — long thin parts bend more, not less.
5. Questions engineers ask
How far apart are dry and conditioned dimensions?+
Should the mould be cut to the dry or the wet state?+
Does annealing solve dimensional problems?+
Does glass fibre stop moisture absorption?+
Related: moisture sensitivity is itself one of the criteria when choosing between PA6 and PA66.