Application · Electrical & electronics

Electrical enclosure materials: settle the thinnest wall before the flame rating

The short answer: structural and live-part housings run on halogen-free FR PA6 + 30% GF — UL94 V-0 at 1.6 mm, tensile 123 MPa, flexural modulus 8,600 MPa. Near heat sources or for sustained high temperature, move to an FR PA66 system; connectors and lead-free reflow parts need PA46; non-structural guards and conduit use FR-PP to control cost. The flame rating must be confirmed at the thinnest wall of the part, not the grade's headline number.

Himing New Material (Zhongshan CSII) Co., Ltd. · IATF 16949 · ISO 9001 · CRCC · Zhongshan, Guangdong

1. Six constraints on an electrical part

UL94 is one of them — and the one most often quoted on its own.

RequirementTypical criterionWhat it drives
UL94 V-0 / 5VARated at the thinnest wallV-0 at 1.6 mm does not mean V-0 at 0.8 mm — measure the thinnest section before quoting
Glow-wire GWIT / GWFIIEC 60695-2-12 / -13Common on unattended appliances; a different test from UL94, not interchangeable
Tracking, CTIIEC 60112Matters for high voltage, moisture or pollution degree 2+; good FR does not imply high CTI
Ball pressureIEC 60695-10-2Insulating parts supporting live parts are assessed at working temperature plus margin
Continuous service temperatureFrom the actual temperature riseHousings near heat sources need a base resin chosen on measured rise, not room temperature
Surface finish / fibre read-throughFor paint-free partsHigh glass loading shows at cosmetic surfaces; fix with tooling/process or lower glass content

2. Five options compared

Typical ranges; measured values for each grade are on its product page, and acceptance follows the TDS and batch COA.

OptionFlameHDTTensileMain drawbackFit
PA6 + 30% GF, halogen-free FRV-0 @ 1.6 mm~195–210 °C123 MPaStiff, cost-effective; fibre read-through on cosmetic facesStructural parts, internal brackets, breaker housings
PA66 + 30% GF, FR (custom)V-0~240–250 °C~150 MPaHigher heat resistance; narrower window, higher costNear heat sources, long high-temperature duty
PA46, FR connector gradeV-0~280 °C—Survives lead-free reflow; highest cost, dedicated processConnectors, SMT parts
FR-PP (V-2 / V-0)V-2 / V-0~100–120 °C22.5 MPaLow density and cost; limited stiffness and heat resistanceNon-structural guards, dividers, conduit
Plain PA6 / ABS, post-treatedNot inherentLow—Relies on structure or coating for flame performanceNot for live-part applications

3. Three common misjudgements

  1. Quoting the datasheet V-0 straight to the housing. The rating is thickness-dependent; if the thinnest section fails, the part fails. Measure the wall first.
  2. Inferring glow-wire from UL94. Different test, different criteria. If the end-product standard requires GWIT/GWFI, it has to be tested.
  3. Ignoring CTI and ball pressure. On high-voltage parts and insulating supports these are frequent certification blockers — confirm data availability at quotation, not at audit.

5. Questions engineers ask

Is V-0 about 1.6 mm or the thinnest wall?+
The thinnest wall. UL yellow cards rate by thickness, so V-0 at 1.6 mm does not carry to 0.8 mm. Send the thinnest section and we quote the grade for that thickness; if a thinner wall must pass, the FR system or the geometry has to change.
If we already pass UL94, do we still need glow-wire?+
Yes. UL94 is a flame-ignition test; glow-wire (IEC 60695-2-12/13) simulates contact with an incandescent element. The criteria are different and neither predicts the other. Unattended appliances — sockets, chargers, control boards — usually need GWIT/GWFI at a temperature set by the end-product standard.
Does a good flame rating mean high CTI?+
No. Flame retardancy and tracking resistance are separate properties, and phosphorus–nitrogen versus halogenated systems move CTI in different directions. For high voltage, moisture or pollution degree 2+, request CTI data on its own — never infer it from V-0.
How do we deal with fibre read-through on visible parts?+
Three levers: lower glass content (GF15–20), a low-read-through fibre/additive package, or tooling and process changes (higher mould temperature, revised gate and venting). For paint-free high-gloss parts, GF30 is usually the wrong starting point — fix the cosmetic requirement first.

Send the thinnest wall and the approval requirements

A grade and FR-system recommendation within 24 hours; samples from 500 kg in 7–10 days.